R
eleasingtheunitfromthebracket
FollowthestepsbelowtoreleasetheunitfromtheMountingbracket.
1.Inserttheflatofasmallflatbladescrewdriver ,orsimilartoolintothereleaseholelocatedon
theflatedgeofthemountingbracketandtwistthescrewdriver90°,sothatthereisasmallgap
betweentheMountingtrimandMountingtray.
Important:T ohelppreventscratchingtheproduct,coverthetipofyourscrewdriverwithasmall
pieceofinsulationtape.
2.Withthescrewdriverinplace ,twistthemountingtrimcounter-clockwiseapproximately10°and
thenliftawayfromtheunit.
8.2ACUInstallation
MountingtheACU-100,ACU-150
Ensurethatthechosenlocationmeetstheproduct’slocationrequirements;refer
to:p.43—Locationrequirements—ACU
Important:
Theinstallationmustonlybeperformedwiththevesseleitheronahardstanding,ortied-up
alongsideapontoonorberth.
1.Usinganappropriatescrewdriver ,undothescrewslocatedonthetopcoverandremovethetop
coverfromtheACU.