P
owersupplycircuitprotection
ProtectthepowersupplyfortheEvolutionsystematthedistributionboardwithafuseorcircuit
breakerthatissuitablefortheACU.Forguidance,refertomainpowerfuseratingstatedontheACU
connectorpanel.Ifindoubt,consultyourlocaldealer.
ACUinternalfuses
TheACUusesstandardautomotivebladefuses.Sparefusesarelocatedontheundersideofthe
removablecover.
Note:
Forclarity ,onlythepowerandfuse-relatedconnectionsareshownintheillustrationabove.
1.Internalpowerfuse(accessibleviatheremovablecover;twistandpulltoaccess).
2.Sea Talkng®fuse(fusepowersupplyfromACUtoSeaTalkng®backbone)
3.Internalpowerfuse(labelledwithtotalpowerconsumedbysystem)
ACUinternalfuseratings
Sea Talkng®3A
A CU-10010A
A CU-150
15A
A CU-20020A
A CU-300
15A
A CU-40040A
88