4.1Generalcablingguidance
Cabletypesandlength
Itisimportanttousecablesoftheappropriatetype
andlength
Unlessotherwisestateduseonlystandardcables
ofthecorrecttype,suppliedbyRaymarine.
Ensurethatanynon-Raymarinecablesareofthe
correctqualityandgauge.Forexample,longer
powercablerunsmayrequirelargerwiregauges
tominimizevoltagedropalongtherun.
Routingcables
Cablesmustberoutedcorrectly,tomaximize
performanceandprolongcablelife.
DoNOTbendcablesexcessively.Wherever
possible,ensureaminimumbenddiameterof200
mm(8in)/minimumbendradiusof100mm(4in).
100 mm (4 in)
200 mm (8 in)
Protectallcablesfromphysicaldamageand
exposuretoheat.Usetrunkingorconduitwhere
possible.DoNOTruncablesthroughbilgesor
doorways,orclosetomovingorhotobjects.
Securecablesinplaceusingtie-wrapsorlacing
twine.Coilanyextracableandtieitoutoftheway.
Whereacablepassesthroughanexposed
bulkheadordeckhead,useasuitablewatertight
feed-through.
DoNOTruncablesneartoenginesoruorescent
lights.
Alwaysroutedatacablesasfarawayaspossible
from:
otherequipmentandcables,
highcurrentcarryingacanddcpowerlines,
antennae.
Strainrelief
Ensureadequatestrainreliefisprovided.Protect
connectorsfromstrainandensuretheywillnotpull
outunderextremeseaconditions.
Circuitisolation
Appropriatecircuitisolationisrequiredfor
installationsusingbothACandDCcurrent:
Alwaysuseisolatingtransformersoraseparate
power-invertertorunPC’s,processors,displays
andothersensitiveelectronicinstrumentsor
devices.
AlwaysuseanisolatingtransformerwithWeather
FAXaudiocables.
Alwaysuseanisolatedpowersupplywhenusing
a3rdpartyaudioamplier.
AlwaysuseanRS232/NMEAconverterwith
opticalisolationonthesignallines.
AlwaysmakesurethatPC’sorothersensitive
electronicdeviceshaveadedicatedpowercircuit.
Cableshielding
Ensurethatalldatacablesareproperlyshielded
thatthecableshieldingisintact(e.g.hasn’tbeen
scrapedoffbybeingsqueezedthroughatightarea).
Blankingplugs
Connectorsnotinuseshouldbeprotectedusing
blankingplugs.
Connectorsontheproductoraccompanyingcables,
thatarenotinuse(notconnected),shouldbe
coveredusingblankingplugsifsupplied.