EasyManua.ls Logo

RayTek Raynger MX4 - User Manual

Default Icon
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
RAYNGER
MX4
HIGH PERFORMANCE
INFRARED THERMOMETER
Rev. D
01/1999
51501
Worldwide Headquarters
Raytek Corporation
1201 Shaffer Road, PO Box 1820
Santa Cruz, CA 95061
Tel: 1 831458 1110
Fax: 1 831425 4561
www.raytek.com
European Headquarters
Raytek GmbH
Blankenburger Str. 135
D-13127 Berlin
Tel: 49 30 4 78 00 80
Fax: 49 30 4 71 02 51
Raytek U.K.
P.O. Box 120
Milton Keynes
Buckinghamshire, MK1 1ZU
United Kingdom
Tel: 44 1908 63 08 00
Fax: 44 1908 63 09 00
Raytek Mexico
13 Poniente, 2313-2° Pisco
Col. la Piedad
72160 Puebla. Pue CP.
Mexico
Tel: 52 22 30 43 80
Fax: 52 22 30 44 38
Raytek China Company
Three Gorges Building Suite 206
N0.A11 Jiu Xian Qiao Road
Chao Yang District
Beijing, China 100016
Tel: 86 10 64 37 02 84
Fax: 86 10 64 37 02 85
Raytek France
5 Avenue du 1
er
Mai
Zae des Glaises
F-91120 Palaiseau
Tel: 33 164 53 15 40
Fax: 33 164 53 15 44
Raytek do Brasil
Rua Dr. Francisco Prestes Maia, 75
18040-650 Jd. Paulistano - Sorocaba - SP
Tel: 55 15 23 36 338
Fax: 55 15 23 36 826
Raytek Japan, Inc.
Honkomagome SO Building
1-1-17 Honkomagome
Bunkyo-ku
113-0021 Japan
Tel: 81 33822-5715
Fax: 81 33822-5712
®

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the RayTek Raynger MX4 and is the answer not in the manual?

RayTek Raynger MX4 Specifications

General IconGeneral
EmissivityAdjustable from 0.10 to 1.00
Response Time500 ms
DisplayBacklit LCD
Power Supply9V battery
Spectral Response8 to 14 µm
Distance to Spot Ratio50:1
Accuracy±1°C or ±1% of reading, whichever is greater
Resolution0.1°C (0.1°F)
Laser TargetingSingle laser
Data LoggingYes
Operating Temperature0 to 50°C (32 to 122°F)
Storage Temperature-20°C to 60°C (-4°F to 140°F)
Weight227 g (8 oz)

Summary

Introduction

Features

Accessories

Functions

User Interface

Details the user interface, including keys and display elements.

Display

Displayed Functions

Lists and describes the functions displayed on the screen.

Batteries

Quick Start

Measurement Quick Start

Provides a quick guide on how to perform a temperature measurement.

Measurement Continuous

Measurement Spot Size

Selecting a Function

Hold Time

Laser ON;OFF

Emissivity

Emissivity Value

Details how emissivity value depends on material and surface characteristics.

Emissivity Adjust

Emissivity Table of Values

Mode: Maximum

Mode: Minimum

Mode: Average

Mode: TC;NTC

Probe Connections (Part 1)

Details how to connect thermocouple and NTC probes to the device.

Probe Connections (Part 2)

Continues the instructions for connecting various types of probes to the device.

Mode: Min-Max Values

Setup

High Alarm

Details how to set and adjust the high temperature alarm threshold.

Low Alarm

Guides the user on how to configure the low temperature alarm setting.

Time Setup

Provides instructions for setting the device's internal clock and time format.

Date Setup

Guides the user on how to set the device's date and date format.

Offset Setup

Explains how to adjust the device's offset for accurate measurements.

Data Logger: How to Store Data

Data Recall

Display: Graphic Display

Display: Auto or Manual Range

Display: Begin (Manual Range)

Display: End (Manual Range)

Display: Cycle

Settings (Part 1)

Lock, °C;°F, Buzzer

Details how to configure the lock function, temperature units (°C/°F), and buzzer settings.

Settings (Part 2)

Settings (Part 3) Printer

Settings (Part 4)

Settings (Part 5) Contact Probes

Appendix A: Troubleshooting

Appendix B: Maintenance

Appendix C: Laser Warning Label

Appendix D: Cautions

Related product manuals