INSTALLATION INSTRUCTIONS
LOCATION
Select a location where the fire can be supervised during operation.
A
n electrical isolation switch must be fitted at the appliance or on an adjacent wall to allow for
emergency shutdown and maintaince.
Installation must meet Australian gas code AS/NZS5601.1-2013.
INSTALLATION CLEARANCES – Clearances from combustible materials
Floor 0mm
Sides 25mm
Top 25mm
Flue outer 25mm
Front 25mm
Back 25mm
INSTALLATION CODES
Note appliance gas type – Natural gas, LPG or ULPG. Should the appliance be the incorrect gas
type, please contact the supplier.
Installers – Please ensure the installation and instruction manuals supplied with this appliance are
supplied to the customer and the customer is trained on how to operate the appliance correctly.
Do not modify the appliance.
Do not exceed maximum rated pressures.
Appliance must be installed with gas installation code (AS/NZS5601.1-2013) and applicable
electrical installation code (AS3000).
Test for gas leaks prior to operating appliance.
Check gas pressures and adjust if incorrect.
FLUE CONFIGURATIONS
For flue configurations 3m or less run an aluminium flexible flue for both the inlet and outlet.
Where lengths greater than 3m are required but less than 5m, use the ELEMENT 1200 XL IOM.
Flue runs 3m or less (75mm diameter Aluminium flexi flue)
Maximum flue runs 3m total length including 3 x 90° bends
Appliance is supplied with a 3m flexible flue run.
Flue can be cut to length as required.
Recommended bend radius 150mm or larger.
Maximum of 3 bends.
Bends must not form a P Trap.
Flue must be clipped to support.
FLUE SPECIFICATIONS
75mm internal diameter twin walled aluminium flexible flue,
supplied in 3m lengths. Flue external diameter approx. 83mm.
U style flue runs must not be installed
7
Cladding between trim
and firebox must be
non-combustible
materials