COMMISSIONING PROCEDURE (continued)
Once the fire is installed:
• Install media.
•
Check for gas leaks.
• Connect powerflue module loom to fan control unit.
• Carry out the lighting procedure.
• Check burner pressures and adjust as per Dataplate.
• Fit access cover and trim.
• Handover instructions to owner.
• Instruct owner on how to operate the fireplace safely.
• Instruct owner how to isolate appliance in an emergency.
Driftwood
• Lay driftwood media in a random arrangement along the entire length of the burner.
• Avoid smothering the burner channel.
• Ensure media is not heaped in areas, spread evenly along.
• Do not add extra media, or combine media types.
• Only the approved supplied media is to be used.
• Refer to Real Flame for technical advice regarding media.
• Do not cover pilot area.
• Do not overfill with media above the pilot cover level.
• Ensure the pilot flame is not impinged by media and can cross light the main burner.
• Do not use any other media than as supplied and recommended by the manufacturer.
• Use of other media may result in explosive media which may cause injury or damage.
Typical setup
IMPORTANT - Do not cover or block pilot area.
MEDIA INSTALLATION
39