EasyManua.ls Logo

Real Flame LANDSCAPE BALANCED - Data Plate Information; Landscape 1000 Data; Landscape 1600 Data

Real Flame LANDSCAPE BALANCED
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DATA PLATE (Affixed to the base of the unit for reference to gas pressure & consumption)
MODEL LANDSCAPE 1000
GAS TYPE
NATURAL GAS @ 0.6 kPa
TEST PRESSURE POINT (HIGH)
INJECTOR SIZE
3 X 2.30mm
GAS CONSUMPTION
41Mj/h
LPG @ 2.60 kPa
TEST PRESSURE POINT (HIGH)
INJECTOR SIZE
3 X 1.10mm
GAS CONSUMPTION
41Mj/h
NATURAL GAS @ 0.30 kPa
TEST PRESSURE POINT (LOW)
INJECTOR SIZE
3 X 2.30mm
GAS CONSUMPTION
29Mj/h
LPG @ 0.90 kPa
TEST PRESSURE POINT (LOW)
INJECTOR SIZE
3 X 1.10mm
GAS CONSUMPTION
29Mj/h
APPROVAL NO: GMK10056
SERIAL NUMBER:
DATE OF MANUFACTURE
MODEL LANDSCAPE 1600
GAS TYPE
NATURAL GAS @ 0.50 kPa
TEST PRESSURE POINT (HIGH)
INJECTOR SIZE
4 X 2.75mm
GAS CONSUMPTION
51Mj/h
LPG @ 2.60 kPa
TEST PRESSURE POINT (HIGH)
INJECTOR SIZE
4 X 1.00mm
GAS CONSUMPTION
51Mj/h
NATURAL GAS @ 0.26 kPa
TEST PRESSURE POINT (LOW)
INJECTOR SIZE
4 X 2.75mm
GAS CONSUMPTION
35Mj/h
LPG @ 1.50 kPa
TEST PRESSURE POINT (LOW)
INJECTOR SIZE
4 X 1.00mm
GAS CONSUMPTION
38Mj/h
APPROVAL NO: GMK10056
SERIAL NUMBER:
DATE OF MANUFACTURE
WEIGHT 132 KG
WEIGHT 195 KG
5