SERIES 2000 PAGE 6.
INSTALLATION INSTRUCTIONS
OPERATOR INSTALLATION - REGULAR ARM
Backplate
Standoff
Control
Base
#8-32x1/4” Mach. Screw
#8 Lockwasher
Mount control unit to backplate using 4 - #8-32
machine screws with standoffs and washers.
Mounting On-Off–Hold Open Switch
And Control Unit
Disassemble On-Off-Hold Open switch and mount
to connector bracket as shown.
Caution– Some local electrical codes require the
switch to be located higher than 6’-6” above floor.
See Electrical Preparation Page 2.
Mounting Operator
Right Hand Shown, Left Hand Opposite
Connector Bracket
1/4-28x3/8” fillister Hd. Mach. Screw
1/4” Lockwasher (Both ends)
Note: Where space between end brackets
and wall does not allow installation of switch
as shown, refer to alternate position, page 6.
Mount operator to backplate using 1/4-28 fillister head screws with lockwashers as shown.
Mount connector brackets to each end of backplate using 1/4-28 screws and lockwashers also.
1/4-28x3/8” Fillister Hd. Mach. Screw
1/4” Lockwasher
#8-32x1/4” Pan Hd. Mach. Screw
#8 Internal Tooth Lockwasher & Nylon Standoff
KEANE MONROE
a member of the record group
MONROE, NC, USA 28111 800 438 1937