EasyManua.ls Logo

Record system 20 - Page 17

Default Icon
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter explanations V2.1_V2.6
2
IRA_B8_EN_2V2_REC_102-020401137 17/ 56
Input/Output → STG →
SÖK:NSK → Speed
30
Miscellaneous → Alarm display
→ Time activation
0
→ CO48 Sandow direct Door with integrated rubber cord (power storage).
For 108/150 mm drives
Only for motors with brake
In France no batteries are allowed
Default parameters:
Parameter Default value
Driving cycle → Close → Hold-
ing force
40
Drive → Brake Open/Close-Position
Drive → Power failure Emergency operation
Input/Output → STG →
AUX1_IN
Broken rubber cord
→ Basic escape route Escape route door for GB with special battery surveillance.
Only allowed with lead-acid battery (British standard).
With
Parameter → Battery Emergency operation
only set-
tings in opening direction are possible.
Battery operation cannot be configured, after a power fail-
ure an emergency opening always occurs according to pa-
rameter
Battery emergency operation
. Once mains voltage
is back, it changes automatically back to the previous op-
erating mode.
The battery is tested once per minute. Should the battery
be defective or insufficiently charged, an emergency open-
ing according to
Parameter → EmergOp Battery
is carried
out, even in case of available mains voltage. Returning to
normal operation is only possible with a new start via
EMERGENCY STOP or FPC902.
Default parameters:
Parameter Default value
Drive → Power failure Emergency operation
Drive → Battery Lead
→ Folding door Australia Folding door for Australia with special driving behaviours.
Different driving behaviours
Higher opening and closing speed
In some ways different behaviour after stop and collision

Related product manuals