5.4 MODULE 4 - SETPOINT OUTPUT PARAMETERS ()
PAR



Setpoint
Standby
Operation

Setpoint Output
Power-up
State
 
Setpoint
Boundary
Type

Setpoint
Enable
Setpoint
Select
 
Setpoint
Assignment

SP2 Output
Off at SP1
Output

Setpoint
Output Logic

Counter
Auto Reset
SP1 Output
Off at SP2
Output
Setpoint
Output
Action
Setpoint
Output
Time-out
 
Setpoint
Value
Setpoint
Output Reset
with Manual
Reset

Setpoint
Annunciator

SP1 Only
SP2 Only


PARAMETER MENU
Select the Setpoint Output to be programmed, starting with Setpoint 1. The
” in the following parameters reflects the chosen Setpoint number. After the
selected setpoint is completely programmed, the display returns to
 .
Repeat steps for Setpoint 2 if both Setpoints are being used. Select
 to exit the
Setpoint programming module.
SETPOINT SELECT



Select  to enable the chosen setpoint and access the setup parameters. If
is selected, the unit returns to  and the setpoint is disabled.
SETPOINT ENABLE
 
Select  to perform either of the Factory Service Operations shown below.
FACTORY SERVICE OPERATIONS



Entering Code 50 will display the model and version (x.x) of the meter. The
display then returns to
. Press the PAR button to exit the module.
VIEW MODEL AND VERSION DISPLAY




Select the display to which the Setpoint is assigned.
SETPOINT ASSIGNMENT







Entering Code 66 will overwrite all user settings with the factory default
settings. The meter will display
 and then return to  . Press the
PAR button to exit the module.
RESTORE FACTORY DEFAULT SETTINGS


Some Setpoint parameters will not appear depending on the Setpoint Assignment and Setpoint
Output Action selected. The Setpoint Parameter Availability chart below illustrates this.
COUNTER ASSIGNMENT (A or B)* RATE ASSIGNMENT
DESCRIPTION
TIMED OUT

BOUNDARY

LATCH

TIMED OUT

BOUNDARY

LATCH


Setpoint Output Time-out Value Yes No No Yes No No

Setpoint Value Yes Yes Yes Yes Yes Yes

Setpoint Output Logic Yes Yes Yes Yes Yes Yes

Setpoint Annunciator Yes Yes Yes Yes Yes Yes

Setpoint Output Power-up State No No Yes No No Yes

Setpoint Boundary Type No Yes No Yes Yes Yes

No Yes No Yes Yes Yes

Counter Auto Reset Yes No Yes No No No

SP1 Output Off at SP2 (SP1 only) Yes No Yes No No No

SP2 Output Off at SP1 (SP2 only) Yes No Yes No No No

Output Reset with Manual Reset Yes No Yes Yes No Yes
Standby Operation (Low ActingOnly)
PARAMETER
* BOUNDARY Setpoint Action not applicable for Counter B assignment.