EasyManuals Logo

red lion PAXCK Bulletin

red lion PAXCK
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #16 background imageLoading...
Page #16 background image
15
PAXR: MAINTAINED (LEVEL) RESET AND INHIBIT
PAXR: MOMENTARY (EDGE) RESET
15




MAINTAINED (LEVEL) RESET AND INHIBIT
The meter performs a reset and inhibits the displays configured as , as
long as activated (maintained action).




INHIBIT
The meter inhibits the displays configured as , as long as activated
(maintained action).

Minimum


Maximum


Counter C


Counter B


Counter A

FACTORYDESCRIPTIONDISPLAY




MOMENTARY (EDGE) RESET
When activated (momentary action), the meter resets the displays configured as
. (Momentary resets improve max. input frequencies over maintained resets.)

Minimum


Maximum


Counter C


Counter B


Counter A

FACTORYDESCRIPTIONDISPLAY

Minimum


Maximum


Counter C


Counter B


Counter A

FACTORYDESCRIPTIONDISPLAY




STORE DISPLAY
The meter holds (freeze) the displays configured as , as long as activated
(maintained action). Internally the counters and max. and min. values continue to
update.




DEACTIVATE SETPOINT MAINTAINED (LEVEL)
The meter deactivates the setpoints configured as , as long as activated
(maintained action). This action only functions with a Setpoint card installed.




DEACTIVATE SETPOINT MOMENTARY (EDGE)
When activated (momentary action), the meter deactivates the setpoints
configured as . This action only functions with a Setpoint card installed.




HOLD SETPOINT STATE
The meter holds the state of the setpoints configured as , as long as
activated (maintained action). This action only functions with a Setpoint plug-in
card installed.

Minimum


Maximum


Counter C


Counter B


Counter A

FACTORYDESCRIPTIONDISPLAY




ACTIVATE SETPOINT MOMENTARY (EDGE)
When activated (momentary action), the meter activates the setpoints
configured as . This action only functions with a Setpoint card installed.

Setpoint 4


Setpoint 3


Setpoint 2


Setpoint 1

FACTORYDESCRIPTIONDISPLAY
When activated (momentary action), the display intensity changes to the next
intensity level (of 4). The four levels correspond to Display Intensity Level
() settings of 0, 3, 8 & 15.




CHANGE DISPLAY INTENSITY LEVEL




ACTIVATE SETPOINT MAINTAINED (LEVEL)
The meter activates the setpoints configured as , as long as activated
(maintained action). This action only functions with a Setpoint card installed.
DISPLAY DESCRIPTION FACTORY

Setpoint 1


Setpoint 2


Setpoint 3


Setpoint 4

DISPLAY DESCRIPTION FACTORY

Setpoint 1


Setpoint 2


Setpoint 3


Setpoint 4


Setpoint 4


Setpoint 3


Setpoint 2


Setpoint 1

FACTORYDESCRIPTIONDISPLAY

Setpoint 4


Setpoint 3


Setpoint 2


Setpoint 1

FACTORYDESCRIPTIONDISPLAY




The meter performs a reset and inhibits the displays configured as , as
long as activated (maintained action).
DISPLAY DESCRIPTION FACTORY

Maximum


Minimum





When activated (momentary action), the meter resets the displays configured as
. (Momentary resets improve max. input frequencies over maintained resets.)
DISPLAY DESCRIPTION FACTORY

Maximum


Minimum


Other manuals for red lion PAXCK

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the red lion PAXCK and is the answer not in the manual?

red lion PAXCK Specifications

General IconGeneral
Brandred lion
ModelPAXCK
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals