5-tOt Totalizer (Integrator) Parameters
8-Out Analog Output Parameters
7-SrL Serial Communication Parameters
DISPLAY PARAMETER
FACTORY
SETTING
USER SETTING
dECPt
* TOTALIZER DECIMAL POINT
0
tbASE
TOTALIZER TIME BASE
KA$
SCFAC
TOTALIZER SCALE FACTOR
1.000
Locut
* TOTALIZER LOW CUT VALUE
-19999
P-UP
TOTALIZER POWER-UP RESET
NO
DISPLAY PARAMETER
FACTORY
SETTING
USER SETTING
bAUd
BAUD RATE
9600
dAtA
DATA BIT
7
PAr
PARITY BIT
Odd
Addr
METER ADDRESS
0
tArE
6ross
Opt
Abrv
PAXS: PRINT GROSS OFFSET
ENTER PRINT OPTIONS
ABBREVIATED PRINTING
NO
NO
NO
YES
INP
PRINT INPUT VALUE
YES
tot
PRINT TOTAL VALUE
YES
HILO
PRINT MAX & MIN VALUES
YES
SPNt
NO
PRINT SETPOINT VALUES
PARAMETER
FACTORY
SETTING
USER SETTING
tYPE
4-20
ASIN
ANALOG ASSIGNMENT
INP
AN-LO
* ANALOG LOW SCALE VALUE
0
AN-HI
* ANALOG HIGH SCALE VALUE
1000
burn
udt
PAXT: PROBE BURN-OUT ACTION
ANALOG UPDATE TIME
LO
0.0
ANALOG TYPE
DISPLAY
400
OFF
nor
NO
AUto
nor
0.0
0.0
2
400
300
OFF
SP-4
USER SETTING
OFF
nor
NO
AUto
nor
0.0
0.0
2
300
OFF
SP-3
FACTORY
SETTING
USER SETTING
FACTORY
SETTING
200
OFF
nor
NO
AUto
nor
0.0
0.0
2
200
100
* SETPOINT VALUE (alternate) ✝
OFF
SP-2
USER SETTING
OFF
nor
SETPOINT ANNUNCIATORS
brn-n
LIt-n
NO
STANDBY OPERATION
Stb-n
AUto
RESET ACTION
rSt-n
nor
OUTPUT LOGIC
out-n
0.0
OFF TIME DELAY
tOF-n
0.0
ON TIME DELAY
tON-n
2
* SETPOINT HYSTERESIS
HYS-n
100
* SETPOINT VALUE (main)
SP-n
OFF
SETPOINT ACTION
ACt-n
SP-1
FACTORY
SETTING
USER SETTING
FACTORY
SETTING
PARAMETERDISPLAY
6-SPt Setpoint (Alarm) Parameters
9-FCS Factory Setting Parameters
✝ Select alternate list to program these values.
26
4-SEC Secondary Function Parameters
FACTORY
SETTING
USER SETTINGPARAMETERDISPLAY
0
0.02
0.00
OFF
ON
PAXS: AUTO-ZERO DELAY
PAXS: AUTO-ZERO BAND
DISPLAY OFFSET - NOT PAXT
UNITS LABEL BACKLIGHT - PAXT ON
At-t
At-b
OFFSt
b-LIt
ICE
2
DISPLAY UPDATE TIME
dSP-t
0.0
MIN CAPTURE DELAY TIME
LO-t
0.0
MAX CAPTURE DELAY TIME
HI-t
PAXT: ICE POINT COMPENSATION
* Decimal point location is model and programming dependent.
3
DISPLAY INTENSITY LEVEL
d-LEv
USER SETTING
FACTORY
SETTING
PARAMETERDISPLAY
PAXT: PROBE BURN-OUT ACTION
2-FNC User Input and Function Key Parameters
DISPLAY PARAMETER USER SETTING
FACTORY
SETTING
USr-1
USER INPUT 1
NO
USr-2
USER INPUT 2
NO
USr-3
USER INPUT 3
NO
F1
FUNCTION KEY 1
NO
F2
FUNCTION KEY 2
NO
rSt
RESET KEY
NO
Sc-F1
2nd FUNCTION KEY 1
NO
Sc-F2
2nd FUNCTION KEY 2
NO
3-LOC Display and Program Lockout Parameters
TOTAL DISPLAY LOCKOUT
MIN DISPLAY LOCKOUT
0
SECURITY CODE
CodE
LOC
LOC
SETPOINT 2 ACCESS
SETPOINT 4 ACCESS
SP-2
SP-4
LOC
LOC
SETPOINT 1 ACCESS
SETPOINT 3 ACCESS
SP-1
SP-3
LOCtOt
LOC
LOC
MAX DISPLAY LOCKOUT
LO
HI
FACTORY
SETTING
USER SETTINGPARAMETERDISPLAY
PAXS: PRINT TARE OFFSET