25
TROUBLESHOOTING
CHECK: Active (lock-out) user input
ENTER: Security code requested
PROGRAM: Module 4 as Hi-t: 0.0 LO-t: 3271.1 (to disable zero chop feature)
PRESS: Reset KEY (If cannot clear contact factory.)ERROR CODE (Err 1-4)
CHECK: Corresponding plug-in card installationMODULES or PARAMETERS NOT ACCESSIBLE
INCREASE: Module 1 filtering, rounding, input range
CHECK: Wiring is per EMC installation guidelines
JITTERY DISPLAY
CHECK: Module 1 programming, Input Range Jumper position, input connections, input signal level“ULUL” in DISPLAY (SIGNAL LOW)
CHECK: Module 1 programming, Input Range Jumper position, input connections, input signal level“OLOL” in DISPLAY (SIGNAL HIGH)
CHECK: Module 1 programming, Input Range Jumper position, input connections, input signal level,
Module 4 Display Offset is zero, press DSP for Input Display
PERFORM: Module 9 Calibration (If the above does not correct the problem.)
INCORRECT INPUT DISPLAY VALUE
CHECK: Module 3 programmingMAX, MIN, TOT LOCKED-OUT
PROGRAM LOCKED-OUT
CHECK: Power level, power connectionsNO DISPLAY
REMEDIESPROBLEM
DISPLAY ZERO’S AT LEVELS BELOW 1% OF RANGE
For further assistance, contact technical support at the appropriate company numbers listed.
PARAMETER VALUE CHART
Programmer ________________ Date ________
PAX MODEL NUMBER ________ Meter# _____________ Security Code __________
1-INP Signal Input Parameters
PAXT: TEMPERATURE SCALE
DISPLAY PARAMETER
FACTORY
SETTING
SCALE
tyPE
rAN6E
PAXT: INPUT TYPE
MODEL DEPENDENT
°F
tc-.
dECPt
COUPL
* DISPLAY RESOLUTION
PAXH: INPUT COUPLE
0
AC
OFFSt
USER SETTING
round
PAXT: DISPLAY OFFSET
DISPLAY ROUNDING INCREMENT
0
1
FILtr
FILTER SETTING - PAXH 0.5
1.0
bANd 10
PtS
ICE
SCALING POINTS
PAXT: ICE POINT SLOPE
2
0.00
INP 1
StYLE
* INPUT VALUE 1
SCALING STYLE - NOT PAXT
0.000
KEY
dSP 1
* DISPLAY VALUE 1
0
INP 2
* INPUT VALUE 2
1.000
dSP 2
* DISPLAY VALUE 2
1000
dSP 4
dSP 5
dSP 3
INP 4
INP 5
INP 3
* DISPLAY VALUE 4
* DISPLAY VALUE 5
* DISPLAY VALUE 3
* INPUT VALUE 4
* INPUT VALUE 5
* INPUT VALUE 3
0
0
0
0.000
0.000
0.000
* Decimal point location is model and programming dependent.
0.000
0
0.000
0
0.000
0
0.000
0
0.000
0
0
0.000
0.000
0
0
0.000
0
0.000
0
0.000
0
0.000
* INPUT VALUE 7
* DISPLAY VALUE 12
* INPUT VALUE 9
* DISPLAY VALUE 14
* INPUT VALUE 8
* DISPLAY VALUE 13
* INPUT VALUE 6
* DISPLAY VALUE 11
* INPUT VALUE 10
* DISPLAY VALUE 15
* DISPLAY VALUE 7
* INPUT VALUE 13
* INPUT VALUE 11
* DISPLAY VALUE 9
* DISPLAY VALUE 16
* INPUT VALUE 15
* DISPLAY VALUE 8
* INPUT VALUE 14
* DISPLAY VALUE 6
* INPUT VALUE 12
* DISPLAY VALUE 10
* INPUT VALUE 16
INP 7
dSP 12
INP 9
dSP 14
INP 8
dSP 13
INP 6
dSP 11
INP 10
dSP 15
dSP 7
INP 13
INP 11
dSP 9
dSP 16
INP 15
dSP 8
INP 14
dSP 6
INP 12
dSP 10
INP 16
USER SETTING
FACTORY
SETTING
PARAMETERDISPLAY
FILTER ENABLE BAND - PAXH 0.020