2.
Using the screwdriver provided, loosen the 7 screws on the spark
arrester.
3.
Remove the spark arrester as shown above.
4.
Check the spark arrester, if necessary, clean or replace.
S. Refit the spark arrester, using the screwdriver provided tighten the 2
screws on the spark arrester.
6. Refit the outlet cover plate, using the screwdriver provided tighten the
4 screws,
TRANSPORTING YOUR GENERATOR
Before storing you REDBACK Generator for long periods:
Ensure the storage area is dry and clean.
Ensure you have drained the fuel.
1.
Drain all petrol into an approved fuel container. Open the fuel tap and
start the engine. Run until engine shuts down.
2.
Disconnect the battery.
22
WARNING!
When transporting you REDBACK Generator:
DO NOT overfill the petrol tank.
Ensure the fuel tap is in the off’ position.
Ensure it is secured to prevent tipping over.
DO NOT operate whilst still on or in your vehicle. Remove from vehicle before use.
Use in a well-ventilated areas.
Avoid storing in direct sunlight.
DO NOT store in sealed area or at high temperatures. Doing so may lead to fuel
becoming volatile and may cause an explosion.
Avoid rough roads. If transporting on rough roads is necessary, drain the generator
before use.