EOS4 SAFETY LIGHT CURTAIN
18 8540733 • 23/03/2016 • Rev.17
English
EOS4XS - EOS4XS2 (SLAVE/SLAVE2 models) - M12, 5-pin primary connectors.
1
Brown
24VDC power supply
2
White
Communication
MASTER-SLAVE
3
Blue
0VDC power supply
4
Black
Communication
MASTER-SLAVE
5
Grey
Ground connection
Table 10 - M12, 5 pins Primary Slave RX
EOS4XM (MASTER models) - M12, 5-pin Secondary Connector.
EOS4XS2 (SLAVE2 models) - M12, 5-pin Secondary Connector.
1
Brown
24VDC power supply
2
White
Communication
MASTER-SLAVE
3
Blue
0VDC power supply
4
Black
Communication
MASTER-SLAVE
5
Grey
Ground connection
Table 11 - M12, 5 pin Secondary RX
Warnings regarding connection cables
For connections with a length of more than 50m, use cables having a cross-section
of at least 1mm
2
.
It is good practice to keep the power supply of the light curtain separate from that
of other electric power equipment (electric motors, inverters, frequency variators)
or other sources of disturbance.
Connect the Emitter and Receiver to the ground outlet.
The connection cables must follow a different route from that of other power
cables.