P121/P121LC/P121RC/P131 Zero Clearance Room Sealed Gas Fireplace 13
FLUEING ARRANGEMENT - HORIZONTAL TERMINATIONS
Regency
®
Direct Vent System (Flex) Horizontal Terminations Only
These ueing systems, in combination with the P121/P121LC/P121RC/P131 Direct Vent Gas Fireplace, have been tested and listed as a direct ue
heater system by Warnock Hersey. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram
on page 12.
Regency
®
Direct Vent (Flex) System Termination Kit (Part# 946-513) includes all the parts needed to install the P121/P121LC/P121RC/P131
with a maximum run of 2 feet.
1) 6-7/8" dia. exible liner (2 ft. length)
2) 4" dia. exible liner (2 ft. length)
3) spring spacers (3)
4) thimble (2)
5) AstroCap termination cap (1)
6) screws (12)
7) tube of Mill Pac (1)
8) plated screws (8)
9) screws #8 x 1-1/2" drill point, stainless steel (4)
Notes:
1) Liner sections should be continuous without any joints or seams.
2) Only Flex pipe purchased from Regency
®
may be used for Flex installations.
3) Regency
®
Direct Vent System (Flex) is only approved for horizontal terminations.