installation
GAS PIPE PRESSURE
TESTING
The appliance must be isolated from the gas supply
piping system by closing its individual manual shut-
off valve during any pressure testing of the gas
supply piping system at test pressures equal to or
less than 1/2 psig. (3.45 kPa). Disconnect piping
from valve at pressures over 1/2 psig.
The manifold pressure is controlled by a regulator
built into the gas control, and should be checked
at the pressure test point.
Note: To properly check gas pressure, both
inlet and manifold pressures should
be checked using the valve pressure
ports on the valve.
1) Make sure the valve is in the "OFF" position.
2) Loosen the "IN" and/or "OUT" pressure tap(s),
turning counterclockwise with a
1/8" wide at screwdriver.
3) Attach manometer to "IN" and/or "OUT"
pressure tap(s) using a 5/16" ID hose.
4) Light the pilot and turn the valve to "ON"
position.
5) The pressure check should be carried out
with the unit burning and the setting should
be within the limits specied on the safety
label.
6) When nished reading manometer, turn
off the gas valve, disconnect the hose and
tighten the screw (clockwise) with a 1/8" at
screwdriver. Note: Screw should be snug,
but do not over tighten.
PILOT ADJUSTMENT
Periodically check the pilot ames. Correct
ame pattern has three strong blue ames:
1 owing around the thermopile, 1 around
the thermocouple and 1 owing across the
burner (it does not have to be touching the
burner).
Note: If you have an incorrect ame pattern,
contact your Regency
®
dealer for
further instructions.
HIGH ELEVATION
This unit is approved in Canada for altitude 0 to
4500 ft. (CAN1 2.17-M91).
GAS LINE INSTALLATION
The gas line can be brought through either the
right, the left side or the bottom of the appliance.
The gas valve is situated on the bottom of the unit.
The gas line connection may be made of rigid pipe,
copper pipe or an approved ex connector. (If you
are using rigid pipe, ensure that the valve can be
removed for servicing.) Since some municipalities
have additional local codes it is always best to
consult with your local authorities and the CAN/
CGA B149 installation code.
For USA installations follow local codes and/or the
current National Fuel Gas Code, ANSI Z223.1.
When using copper or ex connectors use only
approved ttings. Always provide a union so that
gas lines can be easily disconnected for servicing.
Flare nuts for copper lines and ex connectors
are usually considered to meet this requirement.
Important: Always check for gas leaks with a
soap and water solution or gas leak detector.
Do not use open ame for leak testing.
Incorrect ame pattern will have small,
probably yellow ames, not coming into
proper contact with the rear burner or
thermopile or thermocouple.
P121/P131-NG10 System Data
For 0 to 4500 feet altitude
Burner Inlet Orice Sizes: #31
Max. Input Rating 40,000 Btu/h
Min. Input Rating 20,500 Btu/h
Supply Pressure min.5.0" w.c.
Manifold Pressure
(High) 3.8"+/- 0.2"w.c.
Log Set: Ceramic bre, 8 per set.
Vent System: Regency
®
Astrocap
TM
, Regency
®
Direct Vent System (Flex) and Simpson Dura-
Vent Direct Vent System
P121/P131-LP10 System Data
Conversion Kit
For 0 to 4500 feet altitude
Burner Inlet Orice Sizes: #50
Max. Input Rating 39,000 Btu/h
Min. Input Rating 20,600 Btu/h
Supply Pressure min.12.0" w.c.
Manifold Pressure
(High) 11"+/- 0.2" w.c.
Log Set: Ceramic bre, 8 per set.
Vent System: Regency
®
Astrocap
TM
, Regency
®
Direct Vent System (Flex) and Simpson Dura-
Vent Direct Vent System
SIT 829 VALVE DESCRIPTION
1) Gas on/off knob
2) Electronically Operated Hi/Lo
3) Pilot Adjustment
4) Thermocouple Connection - option
5) Outlet Pressure Tap
6) Inlet Pressure Tap
7) Pilot Outlet
8) Main Gas Outlet
9) Alternative TC Connection Point