EasyManua.ls Logo

REMEHA iSense - Page 76

REMEHA iSense
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
76
EN
Outside temperature
The measurement is taken in the boiler and passed to the controller.
Consult the boiler documentation regarding the accuracy of the measurement.
Set temperature range 5 – 35°C
Calibration options Inside and outside temperature sensor: -5 to + 5 in steps of 0.5°C
Control Modulating temperature control
The control can be optimised
Room control Overshoot: maximum 1°C after pre-heating
Temperature variation: less than 0.25°C
Control strategies Room temperature control
Weather-compensated control
3 combination options
Features of the controller
Backlight Colour: blue
Date/time indication Time: 24 h clock. Accuracy: to about 365 seconds per year
Date: day – month – year
Automatic switching to summer time
Programs 2 clock programs with 6 switch points per day
Boiler clock program with 6 switch points per day
16 holiday programs
Day, Night, Frost protection, Summer mode, Fireplace