REMKO CLK SERIES
Before commissioning
■
The connection hose must not
be subject to torsional forces!
■
The fan-assisted heater must not
be pointed in the direction of
the fuel supply!
Paraffin formation with low
outside temperatures
Even at low outside temperatures
it is necessary to ensure that there
is an adequate supply of heating
oil that is capable of flowing.
■
Paraffin formation can start
from temperatures below 5 °C
■
To avoid this appropriate
preventative measures must be
implemented
e.g. Winter-proof EL heating
oil or winter Diesel, heated oil
tank, insulated oil lines etc.
■
Note that fault-free operation
of the Multiflex oil pre-heating
can only be guaranteed if the
unit has been supplied with
electrical power for a long
period of time before starting
■
It is not possible to rectify
paraffin separation that has
already occurred with the
heating. If paraffin has already
formed it is necessary to clean
out the complete fuel system
Air distribution
The units are equipped with a
high performance axial fan. This
fan is designed to specifically and
effectively transport the heated air.
The distribution of the air is
preferably implemented via
ducting or special warm air or
membrane hoses.
The possible lengths depend on
the air-side resistances of the air
ducts used.
■
Use hot air hoses approved by
us (accessories) exclusively
■
Observe the air flow direction
of the hoses with this!
The inner overlapping on the
seams of the hot air hoses must
point in the direction of the air
flow
■
Make sure that the hose or
ducting is securely fastened to
the unit outlet nozzle and any
connection pieces that may be
being used
■
Only suitable air distributors
or air distributors approved by
ourselves should be used for
the air distribution
The units should be checked for
visible defects on the operating
and safety devices as well as
proper installation and correct
electrical connections before
commissioning.
It is essential that the following
points be observed:
■
Set up the units in a stable
position
■
Ensure there is sufficient supply
of combustion air
■
Check that the inlet and outlet
are free
■
Prevent overpressure or
underpressure in the installation
area
■
Ensure that there is sufficient
fuel supply and that it complies
with the respective local
regulations
■
Only use clean EL heating oil or
Diesel fuel
Do not use Bio-Diesel!
■
The replacement of gas
cylinders must take place in an
environment without ignition
sources
Fuel supply
All common gas cylinder sizes
are permitted for the gas supply.
However, a gas cylinder with
at least 11kg filling weight
is recommended. For longer
operation and nominal heat outputs
above 50kW, it is recommended
that the gas be drawn from several
gas cylinders in parallel. (Multi-
cylinder accessories set)
CAUTION
The operability of flexible
fuel lines must be verified
according to local conditions.
They must always be protected
against damage such as from
forklifts, animals, etc.
NOTE
After fulfilling the respective
local regulations as well as
a professional installation of
the unit, the exhaust values
for the forced-air burner must
be checked and adjusted
if necessary by authorised
specialists.
NOTE
The hot air hoses must only
be used in fully extended form
and without any constrictions.
NOTE
The burner setting must be
checked after every change of
location and adapted to the
new environmental conditions
and atmospheric conditions if
necessary.
!