12
REMKO CLK SERIES
1. Move the operating
switch to the "0" (off)
position.
2. Shut off fuel
supply.
3. With longer
periods of inactivity, disconnect
the units from the
mains power supply.
The supply air fan runs on to cool
the combustion chamber and the
heat exchanger and only switches
off after the cooling down phase is
complete.
The fan can switch on and run
several times before the final
shutdown.
Shutdown
s
s
s
Ventilation
In this switch position, the supply
air fan runs permanently.
The units can be used for air
recirculation or ventilation
purposes.
1. Move the operating
switch to the "II"
(Ventilate) position.
Thermostatic regulation and
heating operation are not possible
in this operating mode.
Heating with room thermostat
(Accessories)
The units operate fully
automatically and according to the
room temperature.
1. Pull out the strapping plug 2.
2. Connect the plug 3 of the
room thermostat 4 with the
thermostat socket 1 on the unit.
3. Place the room thermostat 4 at
a suitable location in the room.
The thermostat sensor must not
be located directly in the warm
air flow and must not be placed
directly on a cold floor.
4. Set the desired temperature on
the room thermostat 4.
5. Move the operating
switch to the "I"
(Heating) position.
The unit starts automatically after
a brief burner pre-ventilation if
heat is required and then runs fully
automatically.
3
1
4
CAUTION
Never interrupt the power
supply prior to the completion
of the follow-up cooling
phase.
There is no guarantee
entitlement in case of
damage to the units due to
overheating.
NOTE
In the case of longer periods
of inactivity or if the units are
in storage, ensure that the
fuel tank is always filled with
heating oil or diesel.
NOTE
Indicator light "Operation"
The indicator light signals the
"Heating" operating mode.
There is no display in the
"Ventilate" operating mode
or with the room thermostat
switched off and when the STB
has been triggered.
!