NOTE!
1) When you want to use the EPS function, the setting of the discharge cut
voltage need to be higher than the Battery backup discharge Volt.
2) The battery backup discharge Volt is the min Voltage of the battery.
3) In online mode, the discharge cut voltage is 47V. In EPS mode, the
battery backup discharge voltage is 46V.
4) You can adjust the discharge cut voltage and the battery backup
discharge Voltage or increase Min capacity to adjust the Capacity for
EPS usage in case you have frequently power cut.
L) Reset energy
User can reset the energy record here. Press up or down button to select and press OK to
confirm.
M) Reset error logs
User can reset the error log here. Press up or down button to select and press OK to confirm.
N) Language
User can choose the language English or Deutsch here. Press up or down button to select
and press OK to confirm.
O) About
This interface shows the information of the inverter, such as series numbers and software
version.