Technical data
Filter unit
Item no.
1846 0100
+ 1846 0103
1846 0100
+ 1846 0104
Dimensions
Height of the entire system / mm [inch] 475 [18.7] 410 [16.1]
Height of the lter cartridge / mm [inch] 425 [16.7] 360 [14.2]
Diameter of the lter cartridges / mm [inch] 95 [3.7] 136 [5.6]
Minimum distance to the oor / mm [inch] 40 [1.6] 40 [1.6]
Weight of the lter cartridge / kg [lbs] 1.8 [4.0] 3.2 [7.1]
Operating data
System pressure (without pressure surges) / hPa (bar) [psi] 2000 - 8000 (2 - 8) [29 - 116]
Water temperature / ambient temperature / °C [°F] 4 - 30 [39 - 86]
Flowmeter
Item no. 1846 0101
Sensor unit
Connection thread Inlet 3/8" BSP IG / Outlet 3/8" BSP AG
Inlet pressure (min/max) / hPa (bar) [psi] 1000 - 8000 (1 - 8) [14.5 - 116]
Flow range / l/h [gal/l] 15 - 500 [3.96 - 132]
Pressure loss / hPa (bar) [psi] ≤ 500 (0.5) [7.25]
Measurement (horizontal installation) / % +/- 5
Water temperature (min/max) / °C [°F] 4 - 30 [37.4 - 86]
Ambient temperature (min/max) / °C [°F] 4 - 40 [37.4 - 104]
Dimensions (W x H x D) / mm [inch] 80 x 39 x 42 [3.15 x 1.54 x 1.65]
Installation position Horizontal recommended
Programming and display unit
Graphic display 5 digits in liters and gallons
Counter Decreasing from 99999 to -9999
Dimensions (W x H x D) / mm [inch] 80 x 54 x 29 [3.15 x 2.13 x 1.14]
Power supply, battery type 2 x AA
This unit corresponds to Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This unit may not cause harmful interference and
(2) This unit must accept any interference received, including interference that may cause undesired operation.
The label with the FCC ID and logo is located inside the battery compartment.