TP20probingforcesandovertravellimits
* Nominal at stylus tip.
** Max. at stylus tip.
Probe
module
type
and
stylus
length
XY
trigger
force*
Z
trigger
force*
XY
overtravel
force**
+Z
overtravel
force**
-Z
overtravel
force**
XY overtravel
displacement
+Z overtravel
displacement
-Z overtravel
displacement
LF
10 mm
0.055
N
(5.5 gf)
0.65
N
(65 gf)
0.09 N
(9 gf)
1.15 N
(115 gf)
- ±14° 3.1 mm -
SF
10 mm
0.08
N
(8 gf)
0.75
N
(75 gf)
0.2-0.3 N
(20-30 gf)
3.5 N
(350 gf)
- ±14° 4.0 mm -
MF
25 mm
0.1 N
(10 gf)
1.9 N
(190
gf)
0.2-0.4 N
(20-40 gf)
7.0 N
(700 gf)
- ±14° 3.7 mm -
6-way
10
mm
0.14
N
(14 gf)
1.6 N
(160
gf)
0.25 N
(25 gf)
2.5 N
(250 gf)
9.0 N
(900 gf)
±14° 4.5 mm 1.5 mm
EM1
STD
10 mm
0.08 N
(8 gf)
0.75 N
(75 gf)
0.2-0.3 N
(20-30 gf)
3.5 N
(350 gf)
- ±14° 4.0 mm -
EM2
STD
10 mm
0.08 N
(8 gf)
0.75 N
(75 gf)
0.2-0.3 N
(20-30 gf)
3.5 N
(350 gf)
- ±14° 4.0 mm -
NOTE: The probe module may detach if this value is exceeded.