PH20user'sguide
Document part number H-1000-5261-02-B
ScopeofthePH20user'sguide
This manual is intended to cover the safety requirements of a PH20 system as well as to provide information
about the system, its operation and maintenance.
Pa
g
e 1 of 73PH20 user's
g
uide
19/12/2012file://C:\TEMP\~hh906A.htm

Other manuals for Renishaw PH20

Questions and Answers:

Renishaw PH20 Specifications

General IconGeneral
Storage Temperature-20°C to 70°C
TypeProbe head
CompatibilityRenishaw probe systems
Sensing TechnologyTouch-trigger
Maximum Speed200 mm/s
InterfaceRenishaw probe interface

Summary

Scope of the PH20 user's guide

EC declaration of incorporation for the PH20

Description

Details about the PH20 product, including part numbers and compliance.

Requirements

Section outlining the requirements for the PH20 system.

FCC for PH20

Information to user (FCC section 15.105)

FCC compliance information regarding device operation and interference.

Care of equipment for the PH20 system

Warranty

Information regarding the warranty provided for Renishaw equipment.

Patents for the PH20 head

General safety recommendations for the PH20 system

Appendix 1

Operation and maintenance

Guidelines for the operation and maintenance of the PH20 system.

Warnings

Important safety warnings and precautions for using the PH20 system.

English

CAUTION

Important safety notice regarding system handling and operator training.

Operation and maintenance

Instructions for operating and maintaining the PH20 system.

Warnings

Key safety warnings for users of the PH20 system.

References for the PH20

Abbreviations and acronyms for the PH20 system

PH20 system description

Calibration

Procedure for calibrating the PH20 system using a datum sphere.

PH20 system components

PH20 system connections

PH20 Mounting

PH20 head specification

Dimensions and weight

Physical dimensions and weight specifications for the PH20 head.

Environmental specification - temperature and humidity

Operating conditions for temperature and humidity for the PH20 system.

Electrical specification

PH20 head axis range

PH20 head and stylus modules

Manually mounting/removing the stylus modules to/from PH20

Manually mounting/removing the stylus from the stylus module

TP20 stylus modules

The probe modules

Description of the TP20 probe modules and their kinematic coupling.

Trigger force options

Overview of available trigger force options for TP20 probe modules.

The low force probe module

Details on the low force probe module and its applications.

MCR20NI rack kit

International safety instructions

PH20 system status indicators

PH20 system initialisation

PH20 calibration

MCR20 NI and MCR20

Retrofitting PH20 end cap

Technical data MCR20NI and MCR20 module change rack

Mounting the MCR20 onto the CMM

Aligning the MCR20NI and MCR20 to the CMM axes

MCR20NI and MCR20 alignment and change routine

TP20 probing forces and overtravel limits

TP20 module selection

The probe modules

Details on the various TP20 probe modules available for the PH20.

Trigger force options

Explanation of trigger force options for TP20 probe modules.

Recommended stylus limits

Guidelines for selecting stylus lengths and types for optimal performance.

PH20 system maintenance

General

General maintenance procedures and precautions for the PH20 system.

Styli

Maintenance instructions for stylus balls, threads, and mating faces.