2.5
RMI-Q basics
!
CAUTIONS:
Power supply voltage
Do not exceed 30 V between the black wire and
the screen wire (green/yellow), or the red wire
and screen wire (green/yellow), or the red and
black wires (power supply), as this could result
in permanent damage to the RMI-Q and/or the
customer power supply.
The use of in-line fuses at the machine cabinet
end is recommended to provide protection for the
RMI and cable.
Screen connection
A good connection must be made to machine
ground (star point).
Output stage circuit
Output stage supplies (+ve, –ve) should not be
switched on and off to enable/disable them as this
can cause the over current protection to switch off
the output completely.
Ensure that outputs from the RMI-Q do not
exceed specified current ratings.