RMI-Q installation guide
5.2
Fault-finding
Symptom Cause Action
RMI-Q low battery LED
lit.
Low RMP batteries. Change RMP batteries soon.
Reduced range.
Local radio interference. Identify and remove.
RMP has been enclosed /
shielded by metal.
Review installation.
RMI-Q System Status
LED is continually lit
red.
RMP is not compatible for 0.5
second turn on.
Change RMI-Q configuration to
standard turn on.
Use an RMP with a 'Q' marking.
Probe will not turn off.
Time out off used with level start
option.
Review system setup.