EasyManua.ls Logo

REO REOVIB MFS 268 series - Controller Reset Communication Example

REO REOVIB MFS 268 series
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operating Instructions
Interface Programming
REOVIB MFS 268 - RS 232
14
ELEKTRONIK
5.3 RESET of Controller
Write enable
Word Contents
Send
Contents
Receive
1 C0DE H Adress write key C0DE H Confirmation
2 B5C9 H Value write key B5C9 H Confirmation
3 8000 H +
Control bits
Set Mode bit = 1 C0DE H Confirmation
RS 232 Character string
"CODEB5C98000"+CR
RS 232 Character string
"CODEB5C9CODE"+CR
Write parameter
1
9400 H
Parameter address
+ R / W - Bit
0000 H
Confirmation
2
C009 H
RESET.
0000 H
3 8000 H +
Control bits
Set Mode bit = 1 C0DE H
RS 232 Character string
"9400C0098000"+CR
RS 232 Character string
"94000000CODE"+CR
RESET Allow approximately 0.5 seconds !