Installation Indications, functions and options MessagesCommissioningOperation and function
2/3
Store maximum temperature and Sensor store maximum
temperature
If the store temperature reaches the adjusted maximum temperature, the store
will no longer be loaded in order to avoid damage caused by overheating. If the
maximum store temperature is exceeded, is displayed.
The sensor for store maximum limitation can be selected. The maximum limitation
always refers to the sensor selected.
Switch-on hysteresis: -2 K
If S3 is selected, the differential control will be carried out using S1 and S2. The
temperature at S2 can exceed the adjusted limit temperature, the system will
not switch off. If the value at S3 reaches the limit temperature, the system will be
switched off.
Note:
In systems with 2 stores or store loading in layers, 2 separate menus
(LOAD and LOAD 2) will be displayed.
Loading store 2
In a 2-store system, the second store can be switched off for loading via the pa-
rameter LST2.
If LST2 is adjusted to OFF, the system runs like a 1-store system. The representa-
tion in the display remains the same.
S(1,2)MAX
Maximum store temperature
Adjustment range: 4 … 95 °C
Factory setting: 60 °C
SMXS1(2)
Sensor maximum store tem-
perature
Adjustment range:
1-store system S2, S3
2-store system S4, S5
Factory setting:
1-store system S2
2-store system S4
LST2
Loading store 2
Selection: ON / OFF
Factory setting: ON