PAGE 18
quick tips : You can also adjust the squelch level by keep
pressing button, and then rotating power knob.
Scan Dwell Time Setup
1. Hold button for 2 seconds to get into general setting menu.
2. Press button repeatedly or press Up/Down key on extended
microphone till LCD displays “DWELL TIME”
3. Rotate power knob to set PAUSE/5/10/15 Sec.
4. 5SEC/10SEC/15SEC means the scan resume time. Once the ra-
dio stops on a busy channel, Scan mode will stop and resume for
a period of time.
5. Pause: Once the radio stops on a busy channel, Scan will not keep
going until RX signal is gone for 2 seconds.
Default: 15SEC
This setup can be also applied to CTCSS/DCS scan
LCD Backlight
1. Hold button for 2 seconds to get into general setting menu.
2. Press button repeatedly or press Up/Down key on extended
microphone till LCD displays “BACKLIGHT”
3. Rotate power knob to select LOW/HIGH.
4. LOW:. Low brightness; HIGH:. High brightness
Default: HIGH
Check Working Voltage
1. Hold button for 2 seconds to get into general setting menu.
2. Press button repeatedly or press Up/Down key on extended
microphone till LCD displays “VOLTAGE”