EasyManua.ls Logo

REXROTH CS 530 - Null; Auto-nulling; Gain; Blast in Spinner

REXROTH CS 530
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9
6.4 Null
1. Press ENTER to manually null the minimum and maximum current (in %) to the valve solenoids.
WARNING: Once selected the conveyor or spinner has the ability to turn, and caution must be exercised.
2. Use up and down arrows to adjust the speed so that the motor just begins to turn.
3. Press to end ‘Minimum’ value editing and switch to the ‘Maximum’ value.
4. Do the same for Maximum” except adjust the motor to a safe maximum speed or until the RRM readout
stops to increase.
6.5 Auto-nulling
The nulling of the valve solenoids for the minimum and maximum values can also be accomplished
automatically. Providing a conveyor sensor is being used in the system.
Press the ENTER to start the auto-null process, the text “Auto-nulling” will flash on the screen during procedure.
Auto-null will end after recording the minimum and maximum null values.
6.6 Gain
This is the percentage of valve output increase, introduced on the conveyor during start up, when the vehicle
starts to move, to overcome hydraulic motor pulsing and provide for instant, continuous movement of the
conveyor.
6.7 Blast in Spinner
This is to set the blast rate of the spinner based on the percentage of its maximal output. The default value is
zero, which means the spinner will not blast while the conveyor is blasting.

Related product manuals