16
Press ENTER again to exit.
10 ERRORS
The controller continuously checks for errors during operation. E.g. the below screen shows that the ground
speed is too high. (operator is driving faster than the programmed maximum speed setting)
An audible alarm and error message will display on screen for 4 seconds when an error occurs, then it will go off
and could come back on 3 minutes later if the error is not resolved. Others more serious errors will stay on the
screen until the controller power is cycled or the error is resolved.
Error Messages Suggested Solution Cycle Power Needed?
BLAST2LONG Turn off blast No
DEICE BLST2LONG Turn off blast No
OVERSPEED Slow down, reset max speed No
SPIN OUTPUT Check cables, replace coil Yes
CONV OUTPUT Check cables, replace coil Yes
LIQ OUTPUT Check cables, replace coil Yes
DEICE OUTPUT Check cables, replace coil Yes
NO LIQ DETECT Load material, check sensor Yes
NO CONVEYOR Check cable/sensor No, switches to open loop
NO LIQUID Check cable/sensor Yes
NO DEICE Check cable/sensor Yes
COIL SHORT Check cables, replace coil Yes
0KMh 11:35:07
SPIN‒M SALT‒C LIQ1‒V
0% 0kg 0Lt
LOW GATE: 05 HIGH
Warn: OVERSPEED
Please Slow Down Truck