Guardian PowerVent Training Manual SVC900; Rev 1
Page 34
7. Install the new pilot igniter assembly by
threading the loose ends of the assembly thru
the door hole and pushing the orange grommet
into the hole from the backside. Reattach the
assembly to the mounting bracket with the
Phillips screw.
8. Ensure the grommet is fully seated by tugging
on it. The smaller rubber flange should penetrate
to the front of the door.
9. Reconnect the pilot supply tube (7/16”) and the
main gas supply tube (3/4”), and attach the
orange ignitor wire to the gas control valve.
10. Turn gas supply back on. Turn gas valve to ON.
Turn thermostat up to demand heat. Verify main
burner is on.
11. Set Thermostat not to exceed 120 degrees.
Replace jacket door.