Page 33
HOW TO REMOVE THE GUARDIAN POWERVENT PILOT IGNITER ASSEMBLY
1. Shut off gas supply to water heater. Turn gas
valve to OFF.
2. Unscrew the pilot supply tube (7/16”) and the
main gas supply tube (3/4”), and remove the
ignitor wire from the gas control valve.
3. Remove the four tamper
resistant screws at the
corners of the burner. You
will need a #20 size TORX
head tool.
4. Remove burner access door. Remove the old
door gasket. Clean metal surfaces.
(Gasket will be replaced during reinstallation of
inner door. See gasket shipping package for more
replacement instructions.)
5. Remove the entire pilot igniter assembly by
pulling the orange grommet from the inner door.
Work from the inside of the door.
6. Then remove the igniter from the mounting
bracket with a Phillips screw driver.