Guardian PowerVent Training Manual SVC900; Rev 1
Page 43
5. Unthread wires from retainer clips on
main burner supply tube.
6. Gently grab and pull the sensor from
the mounting hole. Unthread the
remainder of the wiring harness.
7. Replace in reverse order.
8. Rethread wires thru retainer clips on
burner supply tube and reconnect
Molex connect to control valve.
9. Cycle the PowerVent and inspect for
main burner. Set red temperature dial
on thermostat to a safe position not to
exceed 120 degrees.