AIR COOLED
CONDENSING UNITS
92-104921-09-07 (5/16)
Printed in USA
[ ] indicates metric conversions.
Do not destroy this manual.
Please read carefully
and keep in a safe place
for future reference by a
serviceman.
WARNING
THESE INSTRUCTIONS
ARE INTENDED AS AN AID
TO QUALIFIED, LICENSED
SERVICE PERSONNEL FOR
PROPER INSTALLATION,
ADJUSTMENT, AND
OPERATION OF THIS
UNIT. READ THESE
INSTRUCTIONS
THOROUGHLY
BEFORE ATTEMPTING
INSTALLATION OR
OPERATION. FAILURE
TO FOLLOW THESE
INSTRUCTIONS MAY
RESULT IN IMPROPER
INSTALLATION,
ADJUSTMENT, SERVICE,
OR MAINTENANCE
POSSIBLY RESULTING IN
FIRE, ELECTRICAL SHOCK,
PROPERTY DAMAGE,
PERSONAL INJURY, OR
DEATH.
INSTALLATION INSTRUCTIONS
(-)A13, (-)A14 & (-)A16 MODEL SERIES –
13, 14 & 16 SEER
WARNING:
RECOGNIZE THIS SYMBOL
AS AN INDICATION OF
IMPORTANT SAFETY
INFORMATION
ST-A1226-01-00
FEATURING INDUSTRY STANDARD
R-410A REFRIGERANT
earth friendly refrigerant
e
ar
t
h
r
y r
dly
dl
e
n
i
fr
h
NOTE: Actual unit appearance
may vary.

Table of Contents

Questions and Answers

  • S
    sfieldsSep 23, 2025
    What causes a gurgling noise in my Rheem RA1424AJ1NA Air Conditioner's liquid line?
    • D
      Daniel RomeroSep 23, 2025
      If you hear a gurgling or pulsing noise at the expansion device or liquid line of your Rheem Air Conditioner, it's likely due to air or noncondensibles in the system. To resolve this, recover the refrigerant, evacuate the system, and then recharge it.
  • R
    Rachel HenryAug 23, 2025
    Why are the registers sweating in my Rheem RA1424AJ1NA Air Conditioner system?
    • J
      Jessica KingAug 23, 2025
      If the registers in your Rheem Air Conditioner system are sweating, it's likely due to low indoor airflow. Try increasing the blower speed or reducing any restrictions in the airflow. Replacing the air filter can also help.
  • C
    cherylthompsonAug 25, 2025
    How to troubleshoot a Rheem Air Conditioner that will not run?
    • N
      nicole09Aug 26, 2025
      If your Rheem Air Conditioner unit won't run, several factors could be the cause. It could be due to a power outage or loose electrical connection, so check the voltage at the line voltage connections. The thermostat might be out of calibration, so try resetting it. A blown fuse or tripped breaker can also prevent the unit from running, so replace the fuses or reset the breaker. Other potential issues include a defective transformer (check the wiring and replace if necessary), an open high-pressure control (reset it), an open low-pressure control, a defective control board (check diagnostic codes), or miswiring of communications (check communication wiring).
  • M
    Michelle SmithAug 26, 2025
    What to do if Rheem RA1424AJ1NA Air Conditioner compressor short cycles?
    • J
      johnsonamandaAug 27, 2025
      If your Rheem Air Conditioner's compressor is short cycling, several factors could be responsible. First, check the voltage at the compressor terminals; it must be within ± 10% of the nameplate marking when the unit is operating. A defective overload protector could also be the cause, requiring replacement. Lastly, a refrigerant undercharge might be the issue, in which case you should add refrigerant.
  • R
    Roberto JonesAug 27, 2025
    What causes Rheem RA1424AJ1NA Air Conditioner outdoor fan to run but compressor not?
    • J
      Jonathan PattersonAug 27, 2025
      If the outdoor fan of your Rheem Air Conditioner is running but the compressor isn't, it could be due to several reasons. A defective run or start capacitor may be the cause, requiring replacement. The contactor could also be defective and need replacement. Check for correct voltage at the compressor and ensure all connections are tight, as a loose connection could be the problem. The compressor might be stuck, grounded, have an open motor winding, or an open internal overload; wait at least 3 hours for the overload to reset, and if it remains open, replace the compressor. A low-voltage condition could also be the cause, in which case you should add start kit components.
  • C
    Cheryl HarrisSep 16, 2025
    What does it mean when my Rheem RA1424AJ1NA Air Conditioner has high head and low vapor pressures?
    • C
      Cindy TaylorSep 16, 2025
      If your Rheem Air Conditioner has high head pressure but low vapor pressures, there might be a restriction in the liquid line, expansion device, or filter drier. Remove or replace the defective component. Another cause could be a bad TXV, which would need to be replaced.
  • U
    ustephensSep 13, 2025
    Why is the indoor coil of my Rheem RA1424AJ1NA iced, with low vapor pressure?
    • K
      kimericSep 13, 2025
      If you notice low vapor pressure, a cool compressor, and an iced indoor coil in your Rheem Air Conditioner, it could be due to low indoor airflow. Try increasing the blower speed or reducing restrictions, and replace the air filter. If you're operating the unit below 65°F outdoors, consider adding a Low Ambient Kit. Moisture in the system can also cause this issue, so recover the refrigerant, evacuate, recharge, and add a filter drier. Finally, a closed ID circuit could be the problem, requiring repair or replacement of the ID coil.
  • R
    ryan51Sep 14, 2025
    What causes fluctuating head and vapor pressures in a Rheem Air Conditioner?
    • P
      Paul ReynoldsSep 15, 2025
      If your Rheem Air Conditioner is experiencing fluctuating head and vapor pressures, it could be due to TXV hunting. Check the TXV bulb clamp and air distribution on the coil; consider replacing the TXV. Another potential cause is air or noncondensibles in the system, which requires recovering the refrigerant, evacuating, and recharging.
  • A
    adamshenrySep 5, 2025
    Why do my Rheem Air Conditioner registers sweat?
    • C
      Candace TrujilloSep 5, 2025
      Sweating registers in your Rheem Air Conditioner system are typically caused by low indoor airflow. To resolve this, increase the speed of the blower or reduce any restrictions. Also, replace the air filter.
  • D
    donaldnguyenSep 3, 2025
    What does low head and high vapor pressures mean for Rheem Air Conditioner?
    • K
      Kyle HarrisSep 3, 2025
      Low head pressure coupled with high vapor pressures in your Rheem Air Conditioner can point to a bad TXV, which requires replacement. Another potential cause is a bad compressor, which would also need replacing.

Summary

IMPORTANT SAFETY INFORMATION

AWARNINGS

Group of critical safety warnings regarding installation and operation.

INSTALLATION - Location and Environment

INSTALLATION - Leak Testing

WIRING - Control Wiring

WIRING - Power and Grounding

Grounding Procedures

Critical steps for safely grounding the unit.

START-UP - Initial Checks

Start-Up Procedures

Steps to take before initial compressor start-up.

START-UP - System Preparation

Evacuation Procedure

Crucial steps for removing air and moisture from the system.

Final Leak Testing

Methods for detecting leaks after evacuation.

START-UP - Refrigerant Charging

Checking Refrigerant Charge

General procedure for verifying system charge.

START-UP - Refrigerant Adjustment

Gross Charging by Pressures

Initial charge adjustment using system pressures.

Final Charge by Subcooling

Method for precise charge adjustment using subcooling.

START-UP - Finalizing

Checking Refrigerant Charge (cont.)

Final charge adjustments.

DIAGNOSTICS

Electrical Checks Flowchart

Troubleshooting guide for electrical issues.

Cooling Mechanical Checks Flowchart

Troubleshooting guide for cooling system mechanical problems.

General Troubleshooting Chart

Common symptoms, causes, and remedies.

Service Analyzer Charts - Compressor Overheating

Diagnosing compressor overheating issues.

Service Analyzer Charts - Electrical and Flooded Starts

Diagnosing electrical and flooded start issues.

Service Analyzer Charts - Contamination, Lubrication, Slugging

Diagnosing contamination, lubrication, and slugging issues.

Service Analyzer Charts - Flooding and TXV

Diagnosing flooding and thermostatic expansion valve issues.

Service Analyzer Charts - TXV Regulation

Diagnosing TXV regulation problems.

Cooling Mode Troubleshooting Tips

Quick reference for cooling mode issues.

WIRING DIAGRAMS

Single-Phase Models Wiring Diagram

Electrical schematic for single-phase units.

Three-Phase Models Wiring Diagram

Electrical schematic for three-phase units.

Rheem RA1424AJ1NA Specifications

General IconGeneral
ModelRA1424AJ1NA
TypeSplit System Air Conditioner
SEER Rating14
HSPF RatingNot Applicable
RefrigerantR-410A
Voltage208/230V
Phase1
Compressor TypeScroll
Frequency60 Hz
Sound Level (Indoor)Not Available
Dimensions (Indoor Unit)Not Available
Weight (Indoor Unit)Not Available
Cooling Capacity24, 000 BTU/h
Energy Efficiency Ratio (EER)11.5

Related product manuals