51
INDOOR AIRFLOW PERFORMANCE RJNL
M
L
RPM
780
800
830
860
895
940
970
WATTS
455
485
550
615
680
755
825
RPM
780
795
815
850
880
915
945
975
1015
WATTS
390
450
470
530
605
655
735
795
880
RPM
780
795
805
840
870
895
930
955
995
1015
1040
WATTS
370
405
425
490
540
590
655
705
780
830
925
RPM
815
840
870
895
915
945
970
1005
1030
1065
1100
WATTS
385
415
470
530
540
640
700
760
830
910
1005
RPM
875
895
915
940
965
995
1015
1040
1060
1100
1145
WATTS
425
440
510
570
675
675
730
820
880
965
1055
RPM
930
945
965
990
1010
1035
1055
1090
1120
1150
1175
WATTS
460
500
560
605
660
720
790
870
940
1025
1085
RPM
970
995
1015
1035
1055
1070
1105
1130
1155
1180
1225
WATTS
490
540
600
640
710
775
830
910
980
1050
1140
RPM
1030
1045
1060
1075
1100
1120
1145
1170
1195
1225
1260
WATTS
540
595
640
680
760
810
875
950
1020
1095
1175
RPM
1065
1080
1105
1120
1140
1160
1180
1210
1240
1265
1300
WATTS
570
615
680
725
785
850
910
995
1055
1125
1210
RPM
1105
1135
1145
1160
1175
1200
1225
1250
1275
1310
1340
WATTS
595
650
705
755
810
890
950
1020
1100
1175
1255
RPM
1150
1165
1180
1200
1225
1245
1260
1290
1320
1350
1370
WATTS
615
675
730
790
850
915
980
1060
1140
1230
1315
RPM
1195
1215
1225
1245
1260
1290
1320
1335
1360
1375
1400
WATTS
645
700
750
815
880
960
1035
1100
1180
1260
1375
RPM
1235
1255
1275
1300
1320
1335
1350
1370
1385
1405
WATTS
660
735
790
855
930
1000
1075
1150
1225
1320
RPM
1300
1320
1340
1355
1365
1375
1385
1400
WATTS
705
775
840
905
985
1050
1120
1200
RPM
1340
1355
1365
1375
1390
1405
WATTS
745
805
880
940
1020
1100
0.1 [.02] 0.2 [.05] 0.3 [.07] 0.4 [.10] 0.5 [.12] 0.6 [.15] 0.7 [.17] 0.8 [.20] 0.9 [.22] 1.0 [.25] 1.10 [.27] 1.20 [.30] 1.30 [.32] 1.40 [.35] 1.50 [.37]
EXTERNAL STATIC PRESSURE–INCHES OF WATER
VOLTAGE 208-230, 460 - 3 PHASE
CAPACITY5 TON - 13 SEER
AIR
FLOW
CFM
[L/s]
1400
[661]
1500
[708]
1600
[755]
1700
[802]
1800
[850]
1900
[897]
2000
[944]
2100
[991]
2200
[1038]
2300
[1085]
2400
[1133]
DRIVE PACKAGE “L” “M”
MOTOR H.P. 3/4 1
BLOWER SHEAVE 6.4 PITCH DIAMETER 6.4 PITCH DIAMETER
MOTOR SHEAVE 2.8-3.8 PITCH DIAMETER - ADJ. 3.4-4.4 PITCH DIAMETER - ADJ.
TURNS OPEN 0 1 2 3 4 5 6 0 1 2 3 4 5 6
RPM 1095 1040 995 940 890 835 780 1405 1360 1305 1250 1195 1145 1095
5 TON
NOTE: L-Drive left of bold line, M-Drive right of bold line.
Factory sheave settings are shown in bold.