Rheem RKKL Series - Troubleshooting

Rheem RKKL Series
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44
N
OTE: IF THE SYSTEM GOES INTO LOCKOUT, WAIT
30 SECONDS AND RESET THE SYSTEM.
CHECK FLAME SENSOR POSITION AND CONDITION
CLEAN FLAME SENSOR WITH STEEL WOOL
CHECK FLAME SENSOR WIRES AND CONNECTIONS
CHECK FOR 208-230 VAC ACROSS BLOWER
M
OTOR TERMINALS ON CONTROL BOARD
CHECK FOR LINE VOLTAGE AT LOAD SIDE OF
BLOWER CONTACT.
Y
ES
YES
NO
MAIN BURNER FLAME SUSTAINED
YES
N
O
INDOOR BLOWER MOTOR STARTS
A
FTER 45 SECONDS
REPLACE SENSOR
N
O
R
EPLACE INTEGRATED
CONTROL BOARD (IFC)
NO
REPLACE IGNITION CON-
T
ROL
YES
REPLACE BLOWER
MOTOR
CHECK FOR OPEN LIMIT
CHECK FOR OPEN ROLL-OUT CONTROL
CHECK FOR PROPER THERMOSTAT OPERATION
REMOVE VALVE LEAD AT GAS VALVE
IF VALVE CLOSES, RECHECK THE THERMOSTAT
AND WIRING. IF OK, THEN REPLACE VALVE
YES
NO
SYSTEM RUNS UNTIL
CALL FOR HEAT ENDS
TROUBLESHOOTING ENDS
REPEAT PROCEDURE UNTIL TROUBLE FREE
OPERATION IS OBTAINED.
YES
NO
TURN THERMOSTAT OFF
VALVE SHUTS OFF
FLAME SHUTS OFF
YES
INDUCED DRAFT MOTOR STOPS
AFTER 5 SECOND POSTPURGE
YES
YES
CHECK FOR DIRTY FILTERS
CHECK FOR RESTRICTED
AIR-FLOW
CHECK FOR EXHAUST,
INTAKE OR HEAT EXCHANG-
ER BLOCKAGE
CLEAR BLOCKAGE AND
RESET CONTROL
YES
INDOOR BLOWER MOTOR STOPS
AFTER 90 SECONDS
YES
FURNACE STARTS ON LOW OR HIGH
FIRE. FURNACE SWITCHES TO LOW
FIRE AFTER 45 SECONDS WARMUP
IF THERMOSTAT IS CALLING FOR W1.
FURNACE WILL SWITCH TO HIGH
FIRE IF LOW FIRE DOES NOT SATIS-
FY THERMOSTAT DEMAND FOR
HEAT LOAD.