152
Duplex/Inverter Mtr:Hold ENG [0 or 1 / 0 / 1/step]
Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON.
153
Duplex Feed Mtr:Feed
Speed1:Std Speed
ENG [0 or 1 / 0 / 1/step]
Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON.
154
Duplex Feed Mtr:Feed
Speed1:Mid Speed
ENG [0 or 1 / 0 / 1/step]
Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON.
155
Duplex Feed Mtr:Feed
Speed1:Mid-Low Speed *D136
only
ENG [0 or 1 / 0 / 1/step]
This SP is only for D136 machine. Executing this SP on D135/D137/D138 machines may
cause SC error.
Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON.
156
Duplex Feed Mtr:Feed
Speed1:Low Speed
ENG [0 or 1 / 0 / 1/step]
Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON.
157
Duplex Feed Mtr:Feed
Speed2:Std Speed
ENG [0 or 1 / 0 / 1/step]
Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON.
158
Duplex Feed Mtr:Feed
Speed2:Mid Speed
ENG [0 or 1 / 0 / 1/step]
Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON.
159
Duplex Feed Mtr:Feed
Speed2:Mid-Low Speed *D136
only
ENG [0 or 1 / 0 / 1/step]
This SP is only for D136 machine. Executing this SP on D135/D137/D138 machines may
cause SC error.
Operates load for Motors and SOL etc. Pay attention to ON time due to forced load-ON.
7. Input and Output Check
784