If you use this method, calibration updates only the calibration setting that is used to print this job.
Creating a new calibration set
1. Creating a new calibration set, create a name for it and click [Next].
2. Enter a calibration name and an optional comment, and then click [Next].
3. Select a device, and then click [Print].
If using the automated inline sensor
Select the [Automated inline sensor], and then check that [Calibration] is selected in the "Patch
set" list.
If using the optional ES-2000
Select [EFI ES-2000].
4. Configure the settings for the paper, and then click [OK].
5. Measure using ES-2000, and then apply the measurement values.
• The color reproducibility may be improved after executing 0506: [Execute Developer Refreshing]
in the [Machine: Maintenance] group on the [Adjustment Settings for Operators] menu.
• After this procedure is repeated three times, the difference between each color's [D-Max] value in
the measurement column and that in the target column may not be equal to +0.3 or lower and -0.3
or higher for cyan, magenta, and black, or +0.1 or lower and -0.1 or higher for yellow. If this is the
case, print solid images on both sides of 100 sheets of A4 or LTR paper continuously. Desired
results may be obtained.
• If the difference between each color's [D-Max] value in the measurement column and that in the
target column may not be equal to +0.3 or lower and -0.3 or higher for cyan, magenta, and black,
or +0.1 or lower and -0.1 or higher for yellow, color reproducibility may be improved after
printing solid images on both sides of 100 sheets of A4 or LTR paper continuously.
11. Advanced Instructions
322