11. Enter the number of the clogged nozzle that you checked in Step 3 using the number keys,
and then press [Set].
The clogged nozzle is registered.
12. Press [Close] 3 times.
13. Press [Nozzle Recovery].
14. Press [On].
The clogged nozzle is compensated with another nozzle. Prints with the compensated nozzle from
the first printing job after these settings are configured.
15. Press [Close].
16. Press [End].
• It is not reflected in the result of the test print even when [Nozzle Recovery] is set to [On]. When
checking the print result in which the clogged nozzle is recovered, print the recovery check pattern
by using the RIP software. For details, see "Functions on the Main Menu", RIP Settings Guide.
Deleting the Registered Clogged Nozzle
Delete the registered clogged nozzle by nozzle column.
When the clogged nozzle is cleared by performing head cleaning, delete the registered clogged
nozzle. Make sure to switch [Nozzle Recovery] to [Off] after all nozzle defects are cleared.