1.1 Technical Parameter
Model
RD6006
RD6006-
W
RD6012
RD6012-
W
RD6018
RD6018-
W
Input voltage range
6-70.00V
Output voltage range
0-60.00V
Output current range
0-12.00A
0-18.00A
Output power range
0-720W
0-1080W
Input voltage measurement resolution
0.01V
Output voltage setting measurement
resolution
0.01V
Output current setting measurement
resolution
0.01A
Battery voltage measurement
resolution
0.01V
Input voltage measurement accuracy
±(1%+5 digits)
Output voltage accuracy between
setting and measurement
±(0.3%+3 digits)
Output current accuracy between
setting and measurement
±(0.5%+5 digits)
Battery voltage measurement accuracy
±(0.5%+3 digits)
Automatic cut off current value when
charging
100mA
Output ripple typical
250mV VPP@6A
Working temperature range
-10~40
External sensor Temperature detection
range:
-10~100/0~200
External sensor Temperature detection
accuracy:
±3/±6
Constant voltage mode response time
2ms0.1A-5A Load
Constant voltage mode
load regulation
±(0.1%+2 digits)
Constant current mode
load regulation
±(0.1%+3 digits)
Capacity measurement range
0-9999.99Ah
Energy measurement range
0-9999.99Wh
Capacity and energy statistical error
±2
Buck working mode
Voltage drop >1V and >10%
Cooling fan start condition
Output current>8A or
System temperature>45