20063692
14
Installation
5.6 Securing the burner to the boiler
5.6.1 Hinge installation
Install the hinge 4), supplied as standard, as shown in Fig. 8.
Separate the combustion head assembly from the burner
body by removing nut 1) and removing the group A)(Fig. 9).
Fix the group B)(Fig. 9) to the boiler plate 2), inserting the
supplied insulating gasket 3).
5.7 Positioning the probe - electrode
Provide an adequate lifting system of the burner.
The seal between burner and boiler must be
airtight.
Do not turn the ignition electrode but leave it as
shown in Fig. 10.
If the ignition electrode is put near the ionisation
probe, the control box amplifier might be dam-
aged.
Respect the positions shown in Fig. 10.
Fig. 10
D5070
Electrode
Diffuser
2.5 - 3.5 mm
Probe
Probe
Electrode
2.2
~
40 mm
8
°