EasyManua.ls Logo

Riello 40 FS8 - Securing the Burner to the Boiler; Probe and Electrode Positioning

Riello 40 FS8
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
20063692
14
GB
Installation
5.6 Securing the burner to the boiler
5.6.1 Hinge installation
Install the hinge 4), supplied as standard, as shown in Fig. 8.
Separate the combustion head assembly from the burner
body by removing nut 1) and removing the group A)(Fig. 9).
Fix the group B)(Fig. 9) to the boiler plate 2), inserting the
supplied insulating gasket 3).
5.7 Positioning the probe - electrode
Provide an adequate lifting system of the burner.
S7392
Fig. 8
4
WARNING
The seal between burner and boiler must be
airtight.
D5108
Fig. 9
AB
1 3 2
WARNING
Do not turn the ignition electrode but leave it as
shown in Fig. 10.
If the ignition electrode is put near the ionisation
probe, the control box amplifier might be dam-
aged.
WARNING
Respect the positions shown in Fig. 10.
Fig. 10
D5070
Electrode
Diffuser
2.5 - 3.5 mm
Probe
Probe
Electrode
2.2
~
40 mm
8
°

Table of Contents