The BeSMART ON/OFF contact always maintains the same technical char-
acteristics (BeSMART relay, WiFi Box relay, boiler RF receiver relay) wherev-
er it is positioned and these must be respected when connecting the relay
and the components it controls via cable. NOTE: Never exceed the maximum
electrical loads.
NOTE 1
The display range for the room temperature is between -7°C and +50°C.
NOTE 2
The display range for the external temperature is between -40°C and +60°C.
Temperatures outside of these ranges are shown as three dashes “- - -”.
1.5
BeSMART control Class Declaration, according to the ErP Directive
With reference to Delegated Regulation (EU) No. 811/2013, the data in the ta-
ble can be used to complete the product data sheets and energy labelling of
space heaters, combination heaters, packages of space heater, temperature
control devices and solar devices.
Manufacturer/Brand Model
RIELLO SpA / BeSMART BeSMART
Possible BeSMART configurations, the relative configuration classes and the
energy contribution to the system.
Boiler
characteristics
BeSMART conguration
Class and
contribution
Boiler with fixed
delivery temper-
ature (ON/OFF
control)
BeSMART ON/OFF connection I = 1%
Boiler with
variable delivery
temperature
(controlled by
communication
bus)
Connection via communication bus to
the BeSMART. Delivery temperature to
the boiler calculated on the basis of one
room temperature only
V = 3%
Boiler with
variable delivery
temperature
(controlled by
communication
bus)
Connection via communication bus to the
BeSMART. Delivery temperature to the
boiler calculated on the basis of the room
temperature and the external temperature
(given by the external probe or via the web).
VI = 4%