EasyManua.ls Logo

Riello F3 - NOZZLE PLACEMENT

Riello F3
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2903223
6
GB
INTERNAL FACTORY WIRING
CAPACITOR
PUMP VALVE
MOTOR
(COIL)
ELECTRONIC AIR
SHUTTER ASSY
D7328
Key to lay-out:
A - Brown
B - White
C - Blue
D - Black
6 - 120V source activates shutter open
11 - motor lead 120V source
- 120V control lock out alarm terminal
AUX - costant 120V auxiliary terminal - electronic air shutter
RIELLO 40 F3 - F5 SERIES OIL BURNERS EQUIPPED
WITH AN ELECTRONIC AIR SHUTTER INTERNAL FACTORY WIRING
ATTENTION !!
 Do not swap neutral and phase over, follow the diagram shown carefully and carry out a good earth
connection.
Minimum wire size AWG 18.
 All wiring must be done in accordance with existing codes, both national and local.