EasyManua.ls Logo

Riello GS20 - TECHNICAL DATA; Technical data; Overall dimensions

Riello GS20
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2754
2
GB
2. TECHNICAL DATA
2.1 TECHNICAL DATA
2.2 OVERALL DIMENSIONS
2.3 WORKING FIELD
Thermal power (1) 81 220 kW - 70,000 189,000 kcal/h
Natural gas (Family 2)
Net heat value: 8 12 kWh/Nm
3
- 7,000 10,340 kcal/Nm
3
Pressure: min. 20 mbar - max. 100 mbar
Electrical supply Single phase, 220V ± 10%
~
60Hz
Motor 220V / 2.2A
Capacitor 4 µF
Ignition transformer
Primary
220V / 1.25A - Secondary 8 kV / 25 mA
Absorbed electrical power 0.43 kW
(1) Reference conditions:
Temp. 20°C - Barometric pressure 1013 mbar Altitude 0 m above sea level.
FlangeBurner
350 120 389
170
155
33
67
4
5
°
4
5
°
ø
125
298
11
170
Rp 3/4
230
152
280
D4257
200
Combustion head extension, supplied separately.
D5212
0
Thermal power
0.8
1.6
2.4
3.2
4.0
4.8
70,000 90,000 110,000 130,000 kcal/h
80 120100 140 160 kW180
170,000
200 220
150,000 190,000
Pressure in the combustion
chamber – mbar

Related product manuals