Parameter
Name Type Range Default
<frequency>
Consecutive Real
Number
Refer to the introduction in the User's
Guide
900 Hz
Explanation
In the sweep mode, the start frequency, end frequency, center frequency and
frequency span are interrelated and their relations fulfill the following equations.
center frequency = (start frequency + end frequency) /2
frequency span = end frequency - start frequency
Return Format
The query returns the frequency span in scientific notation.
Example
The command below sets the frequency span to 1100 Hz.
:FREQuency:SPAN 1100
The query below returns 1.100000E+03.
:FREQuency:SPAN?