EasyManua.ls Logo

Rigol DG4000 Series

Rigol DG4000 Series
646 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter
Name Type Range Default
<n> Discrete 1|2 1
<user> ASCII String
X000000000000000 to
X111111111111111
X000000000000000
Explanation
In the user-defined harmonics ([:SOURce<n>]:HARMonic:TYPe), users can set the order of
harmonic of the user-defined output harmonic and the highest order is 16. A 16-bit binary
data is used to denote the output statuses of the 16 orders of harmonics with the leftmost bit
denoting the fundamental waveform (it is always X and cannot be modified) and the
remaining 15 bits denoting the second order of harmonic to the 16
th
order of harmonic
respectively from left to right. 1 denotes turning on the output of the corresponding order of
harmonic; 0 denotes turning off the output of the corresponding order of harmonic. For
example, set the 16-bit data to X001000000000001 which denotes outputting the
fundamental waveform, the 4
th
order of harmonic and the 16
th
order of harmonic.
When [:SOURce<n>]
is omitted, the command sets the related parameters of CH1 by
default.
Return Format
The query returns a string between X000000000000000 and X111111111111111.
For example, X001000000000001.