Parameter
Name Type Range Default
-- Keyword AM|FM|PM|ASK|FSK|PSK|PWM|BPSK|QPSK|3FSK|4FSK|OSK AM
Explanation
PWM is only available when Pulse is enabled.
OSK is only available when Sine is enabled.
Return Format
The query returns AM, FM, PM, ASK, FSK, PSK, PWM, BPSK, QPSK, 3FSK, 4FSK or OSK.
Example
The command below selects FSK.
:MOD:TYPe FSK
The query below returns FSK.
:MOD:TYPe?