Parameter
Name Type Range Default
<frequency> Consecutive Real Number 2 mHz to 50 kHz 100 Hz
Return Format
The query returns the frequency in scientific notation.
Example
The command below sets the frequency of the PWM modulating waveform to 300 Hz.
:MOD:PWM:INTernal:FREQuency 300
The query below returns 3.000000E+02.
:MOD:PWM:INTernal:FREQuency?