RIGOL Chapter 6 Sweep
DG4000 User's Guide
6-6
)lg(/)lg( PFtT
start
+=
Wherein, t is the time from the start of the sweep and its range is from 0 to
sweep
T
.
current
F
is the instantaneous frequency currently output.
When Sweep is enabled, press Type to select "Log". An exponential function
curve is displayed on the waveform on the screen, indicating that the output
frequency changes in a logarithmic mode.
Figure 6-2 Log Sweep
Step Sweep
The output frequency of the instrument "steps" from "Start Frequency" to "End
Frequency". The duration of the output signal on each frequency point is